E3MUPS60KHB1S
Easy UPS 3M 60kVA 400V 3:3 UPS, สายแบตเตอรี่โมดูลาร์ภายใน 9Ah 3 สาย ขยายได้ถึง 6 สาย, การเริ่มต้น 5x8
Easy-to-install, easy-to-connect, easy-to-use, and easy-to-service 60 kVA 3-phase UPS. With advanced product features, robust electrical specifications and compact design, the Easy UPS 3M UPS makes business continuity easy for small and medium data centers and other business critical applications. Includes 5x8 start-up service and 3 internal 9 Ah modular battery strings, expandable to 6 for extended runtime.
- Easy UPS 3M is easy to install, connect, use, and service
- Parallel up to 6 Easy UPS 3M UPSs for capacity or redundancy
- High-capacity 9Ah batteries
- Easy Loop test verifies UPS performance before you connect your load, without the need for a load bank
- IP20 (optional IP30, IP40, and IPX2 kits available)
Environmental Data
- การปล่อยก๊าซคาร์บอน
- 73 523 kg CO2 eq.
Use Better
- Packaging made with recycled cardboard
- No
Use Again
- Recyclability potential, in %
- 76
- Take-back
- No
ข้อมูลจำเพาะ
Main
- Main input voltage
- 400 V AC 3 phases
- Other input voltage
- 380 V415 V
- Maximum input current
- 104 A
- Max short time withstand current
- 10 kA
- Input harmonic distortion
- Less than 3 % for full load
- Load power factor
- 0.5 leading to 0.5 lagging without derating
- Cos phi
- 0.99
- Efficiency at full load
- 342...477 V
- Input connection
- 1 hard wire 5-wire (3P + N + E)
- Input frequency
- 40...70 Hz
- Output voltage
- 400 V AC 3 phases
- Other output voltage
- 380 V415 V
- Rated power in W
- 60 kW
- Rated power in VA
- 60 kVA
- Bypass type
- Built-in static bypass
- Harmonic distortion
- Less than 3 %
- Maximum configurable power in VA
- 60 kVA
- Maximum configurable power in W
- 60 kW
- Output harmonic distortion
- < 3% linear load and < 5% non-linear load
- Output overload operation
- 10 minutes at 125% and 60 seconds at 150%
- UPS topology
- Double conversion online
- Waveform type
- Sine wave
- Output frequency
- 50 Hz sync to mains60 Hz sync to mains
Batteries & Runtime
- Battery type
- VRLAInternal modular battery
- Battery voltage
- 240 V
- Included battery module
- 0
- Empty battery slot
- 0