GVSUPS30KB4HS
Galaxy VS UPS 30kW 400V, สายแบตเตอรี่โมดูลาร์สมาร์ทภายใน 2 สาย 9Ah, ขยายได้ถึง 4 สาย, เริ่มต้น 5x8
Highly efficient, easy-to-deploy 30kW, 400V 3-phase UPS. Brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5x8 start-up service and 2 smart high-capacity modular battery strings, expandable to 4 strings for extended runtime
- Up to 99% efficient in eConversion mode
- Maximize availabliity with modular architecture
- Live Swap: Third party verified module replacement with no scheduled downtime
- EcoStruxure IT: Enables resilient, secure, and sustainable IT environments
- 1-year Secure NMC Subscription, allowing the customer to access future firmware updates, is included with purchase
ข้อมูลจำเพาะ
Main
- Main input voltage
- 400 V AC 3 phases380 V AC 3 phases415 V AC 3 phases
- Other input voltage
- 380 V415 V
- Maximum input current
- 54 A
- Max short time withstand current
- 65 kA
- Input harmonic distortion
- Less than 3 % for full load
- Load power factor
- From 0.7 leading to 0.7 lagging without any derating
- Cos phi
- 0.99
- Efficiency at full load
- 340...460 V 400 V
- Input connection
- 1 hard wire 3-wire (3P + E)1 hard wire 5-wire (3P + N + E)
- Input frequency
- 40...70 Hz
- Output voltage
- 400 V AC 3 phases380 V AC 3 phases415 V AC 3 phases
- Rated power in W
- 30 kW
- Rated power in VA
- 30 kVA
- Output connection
- Hard wire 5-wire (3P + N + E) 1
- Bypass type
- Built-in static bypass
- Crest factor
- 2.5
- Harmonic distortion
- Less than 5 %
- Maximum configurable power in VA
- 30 kVA
- Maximum configurable power in W
- 30 kW
- Output overload operation
- 10 minutes at 125% and 60 seconds at 150%
- Output voltage tolerance
- +/-1% after 50ms
- Waveform type
- Sine wave
- Output frequency
- 50 Hz sync to mains60 Hz sync to mains50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised
Batteries & Runtime
- Battery type
- Internal modular batteryVRLA
- Battery voltage
- 480 V
- Extendable runtime
- 0
- Discharge battery voltage
- 384 V DC