GVXL625K1250HS
Galaxy VXL UPS 625kW ขยายได้ถึง 1250kW, 400V, เริ่มต้น 5x8
Highly efficient, compact, modular 625 kW (400V) 3-phase UPS with Live Swap that is scalable up to 1250 kW. Delivers top performance for colocation, large and extra-large data centers, as well as critical infrastructure in commercial and industrial, and cloud and service provider facilities. This EcoStruxure connected UPS features up to 99% efficiency with patented eConversion technology.
- Up to 99% efficient in eConversion mode
- Maximize availability with modular, scalable architecture
- Live Swap: Third party verified module replacement with no scheduled downtime
- Unlock resiliency and sustainability with access to EcoStruxure software
Environmental Data
- การปล่อยก๊าซคาร์บอน
- 464 ton CO2 eq.
Use Better
- Packaging made with recycled cardboard
- Yes
- ประสิทธิภาพพลังงาน
- Energy efficient product
- Product contributes to saved and avoided emissions
- ใช่
Use Again
- Recyclability potential, in %
- 65
- Take-back
- No
ข้อมูลจำเพาะ
Main
- Main input voltage
- 380 V AC 3 phases400 V AC 3 phases415 V AC 3 phases
- Other input voltage
- 400 V
- Maximum input current
- 1140 A
- Max short time withstand current
- 100 kA
- Input harmonic distortion
- Less than 3 % for full load
- Load power factor
- 0.5 leading to 0.5 lagging without derating
- Efficiency at full load
- 340...460 V 400 V
- Input frequency
- 40...70 Hz
- Output voltage
- 380 V AC 3 phases400 V AC 3 phases415 V AC 3 phases
- Other output voltage
- 400 V
- Rated power in W
- 625 kW
- Rated power in VA
- 625 kVA
- Bypass type
- No bypass
- Crest factor
- 3
- Harmonic distortion
- < 3 %
- Maximum configurable power in VA
- 1250 VA
- Maximum configurable power in W
- 1250 kW
- Output harmonic distortion
- < 1% linear load and < 5% non-linear load
- Output overload operation
- 10 minutes at 125% and 60 seconds at 150%
- UPS topology
- Double conversion online
- Waveform type
- Sine wave
- Output frequency
- 50...60 Hz
Batteries & Runtime
- Battery type
- VRLAลิเธียมไอออน (ลิเธียม-ไอออน)External battery system
- Battery voltage
- 480...576 V DC
- Discharge battery voltage
- 384 V DC
- Battery charging power
- 125 kW full load